0° superheat — TXV was feeding too much.
Adjusted the valve, recovered some charge, and brought SH back up.
#HVAC #HVACTech #TXV #ServiceCall #Superheat by @erichvacguy
62
a month ago
Download
This one wasn’t too bad😂 what’s the tightest space you’ve been in?
#HVAC #HVACTech #AtticLife #CrawlSpace #TucsonHVAC by @erichvacguy
5
3 days ago
Download
Compressors usually don’t go bad for no reason... Grounded compressor replacement + airflow adjustment  #HVAC #HVACTech #TucsonHVAC
#ServiceCall #Compressor by @erichvacguy
10
10 days ago
Download
My girl My girl Myyy girl 💕 I love this
girl with all I got 🔒 #rideordie #mygirl @reynaa13 by @erichvacguy
3
23 days ago
Download
Low airflow + clogged filter drier
Restricted liquid line and restricted air.
Both choking the system
#HVAC #HVACTech #superheat
#ServiceCall #POV by @erichvacguy
18
a month ago
Download
2 year old compressor already failed. 35 amps, out on thermal, compression ratio 1.96. Wasn’t pumping.
#HVAC #HVACTech #TucsonHVAC #ServiceCall #Compressor by @erichvacguy
17
a month ago
Download
454B TXV flooding the compressor.
Airflow was high, superheat sat at O.
Iced the bulb and it jumped to 20. Put it back on the line and it went right back to dumping liquid
#HVAC #HVACTech #staticpressure #subcool #superheat by @erichvacguy
29
a month ago
Download
No cool.
Blower motor was dead so I replaced it.
Then found the bypass stuck wide open ton dumping air — forced it closed.
Checked airflow after... 1960 CFM on a 4 ton.
Dropped it to 1610/1555 so the coil can actually work. #hvactechnician #subcool #Superheat #hvac #pov by @erichvacguy
10
2 months ago
Download
No cool call on a 2 year old Goodman Let me know what yall think about
this diagnostic?#hvactechnician #subcool #Superheat #ACRepair
#POV by @erichvacguy
54
2 months ago
Download
These Carrier A2L 454B sensors and boards are always going bad. Replaced the bad sensor then checked the entire unit for proper operation. Pressures, temps, and airflow all good after the swap. #HVAC #HVACTech #subcool #Superheat #POV by @erichvacguy
32
2 months ago
Download
Homeowner said the unit would run for about 30 minutes, shut off, come back on a couple minutes later, run another 10, then shut off again… short cycling and not cooling right.
Sensing bulb wasn’t properly secured on the suction line and airflow was off. Got the bulb seated right and set airflow to 371 CFM per ton from 466.
#hvactechnician #nocool #txv #subcool #superheat by @erichvacguy
69
3 months ago
Download

Download All

Save the photos and videos currently loaded on this page.

0Photos
0Videos
Ready to download 0 / 0

Keep this tab open until your download is ready.

back to up